TCXO (Temperature Compensated Crystal Oscillator) List
Click [
] to sort.
Clicking it again switches the ascending order to descending order.
Hold down the [Shift] key to select multiple items.
| Model | Recommended application |
Nominal Freq. (MHz) |
Package Size (mm) |
Operating temp. range (°C) |
Freq. / Temp. charac- teristics |
Supply voltage | Current consumption | RoHS | Pb free | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| min | max | L | W | H | min | max | (×10-6) | (Vcc) | (mA) | ||||
| Model | Recommended application |
min | max | L | W | H | min | max | (×10-6) | (Vcc) | (mA) | RoHS | Pb free |
| Nominal Freq. (MHz) |
Package Size (mm) |
Operating temp. range (°C) |
Freq. / Temp. charac- teristics |
Supply voltage | Current consumption | ||||||||
| NT2520SB | Mobile Communications | 13 | 27.456 | 2.5 | 2.0 | 0.9 | -30 | +85 | ±0.5 | +2.8 | 1.5 | ||
| NT2016SA(with AFC) | Mobile Communications | 13 | 26 | 2.0 | 1.6 | 0.8 | -30 | +75 | ±2.5 | +2.8 | 1.5 | ||
| NT2520SA(with AFC) | Mobile Communications | 13 | 26 | 2.5 | 2.0 | 0.8 | -30 | +75 | ±2.5 | +2.8 | 1.5 | ||
| NT3225SA(with AFC) | Mobile Communications | 10 | 26 | 3.2 | 2.5 | 1.0 | -30 | +75 | ±2.5 | +3.0 | 1.5 | ||
| NT3225SA | Mobile Communications | 10 | 26 | 3.2 | 2.5 | 1.0 | -30 | +75 | ±2.5 | +3.0 | 1.5 | ||
| NT3225SA | Mobile Communications | 13 | 27.456 | 3.2 | 2.5 | 1.0 | -30 | +85 | ±0.5 | +2.8 | 1.5 | ||
| NT5032SC(with AFC) | Mobile Communications | 12.6 | 26 | 5.0 | 3.2 | 1.5 | -30 | +75 | ±2.5 | +3.0 | 1.5 | ||
| 5925A-AQP50 | Fixed Communication | 10 | 25 | 25 | 25 | 15 | -40 | +85 | ±5 | +5 | 5 | (*1) | |
| 5925A-AML50 | Fixed Communication | 10 | 25 | 25 | 25 | 15 | -30 | +75 | ±2 | +5 | 5 | (*1) | |
| 5925A-ALH50 | Fixed Communication | 10 | 25 | 25 | 25 | 15 | -20 | +70 | ±1.5 | +5 | 5 | (*1) | |
| 5925A-AKG50 | Fixed Communication | 10 | 25 | 25 | 25 | 15 | -20 | +60 | ±1 | +5 | 5 | (*1) | |
| 5925A-AJD50 | Fixed Communication | 10 | 25 | 25 | 25 | 15 | -10 | +50 | ±0.5 | +5 | 5 | (*1) | |
| 5921A-AKG50 | Fixed Communication | 10 | 20 | 21 | 13 | 9.2 | -20 | +60 | ±1 | +8 | 5 | (*1) | |
| 5921A-AMG50 | Fixed Communication | 10 | 20 | 21 | 13 | 9.2 | -20 | +60 | ±2 | +8 | 5 | (*1) | |
| 5930D-AJD70 | Fixed Communication | 10 | 25 | 30 | 30 | 16 | -10 | +50 | ±0.5 | +5 | 15 | (*1) | |
| 5930D-AKG70 | Fixed Communication | 10 | 25 | 30 | 30 | 16 | -20 | +60 | ±1 | +5 | 15 | (*1) | |
| 5930D-ALH70 | Fixed Communication | 10 | 25 | 30 | 30 | 16 | -20 | +70 | ±1.5 | +5 | 15 | (*1) | |
| 5930D-AML70 | Fixed Communication | 10 | 25 | 30 | 30 | 16 | -30 | +75 | ±2 | +5 | 15 | (*1) | |
| 5930E-AKG00 | Fixed Communication | 10 | 25 | 30 | 30 | 16 | -20 | +60 | ± 1 | +12 | 15 | (*1) | |
| 5930E-ALH00 | Fixed Communication | 10 | 25 | 30 | 30 | 16 | -20 | +70 | ± 1.5 | +12 | 15 | (*1) | |
| 5930E-AML00 | Fixed Communication | 10 | 25 | 30 | 30 | 16 | -30 | +75 | ±2 | +12 | 15 | (*1) | |
| 5930E-BKG00 | Fixed Communication | 25 | 60 | 30 | 30 | 16 | -20 | +60 | ±1 | +12 | 15 | (*1) | |
| 5930E-BLH00 | Fixed Communication | 25 | 60 | 30 | 30 | 16 | -20 | +70 | ±1.5 | +12 | 15 | (*1) | |
| 5930E-BML00 | Fixed Communication | 25 | 60 | 30 | 30 | 16 | -30 | +75 | ±2 | +12 | 15 | (*1) | |
| 5930E-PKG00 | Fixed Communication | 60 | 150 | 30 | 30 | 16 | -20 | +60 | ±1 | +12 | 40 | (*1) | |
| 5930E-PLH00 | Fixed Communication | 60 | 150 | 30 | 30 | 16 | -20 | +70 | ±1.5 | +12 | 40 | (*1) | |
| 5930E-PML00 | Fixed Communication | 60 | 150 | 30 | 30 | 16 | -30 | +75 | ±2 | +12 | 40 | (*1) | |
| 5936L-GJD70 | Fixed Communication | 0.7 | 10 | 36.2 | 27.8 | 15 | -10 | +50 | ± 0.5 | +5 | 18 | (*1) | |
| 5936L-AJD70 | Fixed Communication | 10 | 22 | 36.2 | 27.8 | 15 | -10 | +50 | ± 0.5 | +5 | 18 | (*1) | |
| 5920A-AQJ70 | Fixed Communication | 10 | 25 | 20 | 20 | 10 | -30 | +60 | ± 5 | +5 | 15 | (*1) | |
| 5920A-APG70 | Fixed Communication | 10 | 25 | 20 | 20 | 10 | -20 | +60 | ± 3 | +5 | 15 | (*1) | |
(*1) The products are RoHS compliant as to lead in solder for servers, storage array systems, network infrastructure equipment for switching, signaling, transmission, network management for telecommunications also by the annex.
Specifications described in this site are subject to change without notice for improvement.
For more information such as "Reflow Soldering", "Precaution for use", and etc, please refer the Application Note.