Ultrasonic probe is a very important sensor which generate acoustic signals and also detect returned signals. The performance and imaging quality of ultrasonic scanner are highly affected by the characteristic and the structure(piezoelectric material, matching layer and acoustic lens) of probe.
NDK has a probe line up for each application and can produce customer's designed products.
The customized transducers based on long experiences and proven result with past development records over 1,500 kinds of transducers.

| Probe type | Feature | Application | Central frequency |
Element | Radius of curvature |
Main Product (Array Module) |
|
|---|---|---|---|---|---|---|---|
![]() Linear type |
wide footprint and keep same field of view at deep part. |
1) Breast, Thyroid and Arteria carotis of vascular application. 2) Tendon, Rheumatology application. 3) The thickness measurement of Body fat and Musculus. 4) Crack detection of metal and concrete. |
2.5MHz | 12MHz |
64ch | 256ch |
- | 7.5MHz Linear |
Sample Data |
10MHz Linear |
Sample Data |
||||||
![]() Convex(Curved) type |
wide footprint, field of view will be spreaded at deep part. |
1) Abdominal application. 2) Tendon, Rheumatology application. 3) Diagnoses organs. |
2.5MHz | 7.5MHz |
64ch | 192ch |
5R | 80R |
3.5MHz Convex (Curved) |
Sample Data |
6MHz Convex (Curved) |
Sample Data |
||||||
![]() Phased(Sector) type |
small footprint, field of view will be spreaded widely at deep part. |
1) Cardiac application. 2) Transesophageal application. 3) Abdominal application. |
2MHz | 7.5MHz |
32ch | 128ch |
- | 2.5MHz Phased (Sector) |
Sample Data |
![]() Single type |
A) The measurement of distance. B) B mode scanning by mechanical rotation. |
1) Measurement of eye axial length. 2) Transesophageal application. 3) Transvaginal and Transrectal application. 4) Transurethral application. 5) The blood flow measurement with Doppler. |
2MHz | 22MHz |
- | - | 7.5MHz Single type |
Sample Data |
20MHz Single type |
Sample Data |
||||||
| Probe type | Feature | Application | Central frequency |
Element | Radius | Main Product (Probe) |
|
|---|---|---|---|---|---|---|---|
![]() Linear type |
Real time 3D imaging with wide footprint and keep same field of view at deep part. |
Breast, Thyroid and Arteria carotis of vascular application. | 7.5MHz | 11MHz |
128ch | 192ch |
- | Mechanical Scanning 3D 8MHz Linear |
Sample Data |
![]() Convex(Curved) type |
Real time 3D imaging with wide footprint, field of view will be spreaded at deep part. |
1) Abdominal application. 2) Transvaginal and Transrectal application. |
3.5MHz | 6.5MHz |
128ch | 192ch |
10R | 40R |
Mechanical Scanning 3D 4.5MHz Convex(Curved) |
Sample Data |
High frequency probe can get the fine imaging with good resolution.
However the imaging of deep part will be smudgy due to wave length is short.
Meanwhile the imaging resolution of low frequency probe is low but ultrasonic wave can reach at deep part. The scanning depth and resolution are mainly determined by the frequency of probe.
| Frequency | Resolution | Penetration | Possible scanning depth |
|---|---|---|---|
| High | Fine | Weak | Shallow |
| Low | Rough | Strong | Deep |
Specifications described in this site are subject to change without notice for improvement.
Copyright© 1997- NIHON DEMPA KOGYO CO., LTD.